Lainox Compact 6x 1/1 GN Electric Injection Combi Oven COES061R
Product Description
The Lainox Compact COES061R is a six-grid, full 1/1 GN electric combi oven operating on a single phase supply. It uses direct steam injection to generate moisture, giving operators control...
Specifications
- Colour
- Silver
- Dimensions
- 880(H) x 510(W) x 800(D)mm
- Gn size
- 1/1 GN full
- Temperature range
- 30°C to 300°C
Downloads
Product Description
The Lainox Compact COES061R is a six-grid, full 1/1 GN electric combi oven operating on a single phase supply. It uses direct steam injection to generate moisture, giving operators control over convection, steam, and combination cooking modes. The manual control interface is straightforward to learn and stores up to 99 cooking programmes, each configurable across up to four sequential steps — useful for products that need distinct phases such as probe-based roasting or regeneration sequences.
In a working kitchen, this oven performs well in sites where output demand is consistent but not extreme — think hotel restaurants, care homes, school kitchens, or busy café operations. The injection steam system responds quickly, and the multipoint core temperature probe helps maintain consistency across a full load without relying on operator judgement alone. At six grids, throughput is meaningful without the space commitment of larger ten-grid units.
Practical advantages that matter in day-to-day service:
- Single phase connection removes the need for three phase electrical supply — a genuine practical advantage in many older or smaller premises
- 99 programmable cooking cycles reduce reliance on individual cook skill and support menu consistency
- Up to four cooking steps per programme allows complex multi-stage processes to run unattended
- Multipoint probe monitoring supports accurate core temperature results across different load sizes
- Robust stainless steel construction holds up under regular commercial use and is straightforward to clean down
On installation, the single phase electrical requirement is a notable point — it makes this model accessible to kitchens where upgrading to three phase supply would be disruptive or costly. That said, you will still need to confirm your available amperage with an electrician before installation, as combi ovens draw a significant load. The oven weighs 73kg, so access and positioning should be planned in advance. Adequate ventilation is essential — connection to a canopy or purpose-designed extraction system is required, not optional. Water connection and drainage are also needed for the injection steam system; water quality and hardness in your area will affect descaling frequency.
This model is well suited to operations cooking for moderate covers — typically in the range of 40 to 150 meals per service — where single phase supply is a constraint or a preference. It is a practical fit for care homes, education catering, and smaller hotel or pub kitchen operations. If your site is running significantly higher volumes or needs greater simultaneous tray capacity, a larger ten-grid or higher-output model from the range is likely to be the more appropriate choice. Equally, if your output is modest and counter space is at a premium, a smaller four-grid unit may serve you just as well.
If you are weighing up whether this oven is the right size for your kitchen or want to talk through the installation requirements in more detail, the team is happy to work through it with you before you commit.
Key Features
- Six full 1/1 GN grid capacity with direct steam injection system
- Single phase electrical connection suitable for older or smaller premises
- Stores up to 99 manual cooking programmes for consistent results
- Each programme configurable across up to four independent cooking steps
- Multipoint core temperature probe ensures accurate results across varied loads
Operational Benefits
- Single phase supply removes costly electrical upgrade requirements on many sites
- Programmable cycles reduce dependence on individual cook experience and skill
- Multi-step programmes allow complex dishes to run unattended through service
- Probe-controlled cooking delivers consistent core temperatures across full tray loads
- Compact six-grid footprint suits kitchens where space and output are balanced
Specifications
- Colour
- Silver
- Dimensions
- 880(H) x 510(W) x 800(D)mm
- Gn size
- 1/1 GN full
- Temperature range
- 30°C to 300°C
- Warranty
- 1 Year
- Weight
- 73kg
Downloads
Frequently Asked Questions
- Single phase combi ovens are a practical choice for many commercial kitchens — particularly smaller or older premises where a three phase supply is not available or would be expensive to install. The trade-off is typically in recovery speed under heavy continuous loading compared to three phase equivalents, so this model is best suited to sites with moderate rather than very high throughput demands. For high-volume operations running back-to-back full loads through service, a three phase unit is usually the more appropriate specification.
- You will need a suitable single phase electrical connection with sufficient amperage — confirm this with a qualified electrician before installation, as combi ovens draw a substantial load. The oven also requires a mains cold water supply and a floor or tray drain for condensate. Ventilation to a commercial canopy or extraction system is a requirement, not a recommendation. Water hardness in your area will affect how frequently the unit needs descaling, so it is worth factoring a water softener into the installation plan if you are in a hard water region.
- At six full 1/1 GN grids, this oven is typically well matched to operations serving roughly 40 to 150 covers per service, depending on the menu and how the oven is used within the wider kitchen workflow. Care homes, school kitchens, and smaller restaurant or hotel operations tend to find this size sits well within their production needs. If your volume is consistently towards the higher end of that range or your menu relies heavily on the combi oven as a primary cooking method, it is worth discussing whether a larger capacity unit would give you more headroom during peak service.