Instanta

Instanta CTS19F6 19 Litre Counter Top Water Boiler

SKU: CTS19F6

£724.00(£868.80 inc VAT)

Get a quote

Request a callback

Leave your details and we will call you back about Instanta CTS19F6 19 Litre Counter Top Water Boiler.

Delivery Information

Price Match

  • In the event of equipment failure any parts needed will be provided 2
  • In the event of equipment failure an engineer will be sent for an onsite repair 2
  • Equipment can be connected to a single phase power supply – must be installed by a competent person
  • Equipment that should be connected to a suitably rated outlet - must be installed by a competent person
  • This product is Made in Britain

The Instanta CTS19F6 is a counter top water boiler designed for commercial settings where a reliable, uninterrupted supply of hot water is needed throughout a full service period. It connects directly to a mains water supply and fills automatically, removing the need for manual refilling during service. Integrated point-of-use filtration is built in, which protects water taste, reduces scale accumulation, and removes the need for a separate inline filter unit.

In practice, this kind of unit earns its place in cafés, workplace restaurants, hotel serveries, and similar operations where hot beverage demand is steady rather than extreme. The capacity is sufficient to handle repeated rounds without the recovery pauses that can create pressure during a busy morning or lunchtime service. Electronic temperature control keeps the water at a consistent serving temperature across the day, so the first cup served and the last are drawn from water that is equally ready.

Day-to-day operational advantages include:

  • Integrated filtration protects water quality without additional inline equipment
  • Auto-fill operation keeps the boiler ready throughout service without manual intervention
  • Electronic temperature control maintains consistent water temperature across long service periods
  • Counter top footprint preserves floor space and keeps the unit accessible during service
  • Hardwired single-phase connection provides a stable, permanent supply suited to daily commercial use

Installation does require a hardwired single-phase electrical connection — a standard plug socket will not suffice, so electrical work should be planned and budgeted before the unit arrives. A mains cold water feed and an accessible stop valve are also needed at the installation point. It is worth checking that the counter surface can bear the weight of the unit when full before deciding on placement.

The CTS19F6 sits in a practical middle ground: more capable than a small top-up boiler, but appropriately sized for sites where a large floor-standing urn would be unnecessary. For operations with a high volume of covers in tight service windows, or where multiple service points need supplying simultaneously, a higher-capacity or higher-output model may be a better fit.

If you would like to talk through the unit's suitability for your service volume or installation setup, the team is happy to help before you place an order.

Frequently asked questions

Is the CTS19F6 suitable for a busy café serving a high volume of hot drinks?

The CTS19F6 handles moderate but consistent hot beverage demand well — typical café service, workplace catering, and hotel servery environments are all reasonable fits. For sites serving a high volume of covers in tight service windows, or running multiple service points simultaneously, it is worth discussing whether a higher-capacity or higher-output model would be a better match for your throughput.

What are the installation requirements for this water boiler?

The unit requires a hardwired single-phase electrical connection, so a standard plug socket is not suitable and a qualified electrician will need to be involved. You will also need a mains cold water supply and an accessible stop valve at the point of installation. Counter load-bearing capacity and depth should be checked before positioning, as the unit carries meaningful weight when filled.

Does the integrated filtration mean I do not need a separate water filter?

The CTS19F6 includes built-in point-of-use filtration, which means a separate inline filter unit is not required as part of the installation. The integrated filter helps protect water taste and reduce scale build-up over time, though like any filtration system it will need periodic replacement as part of routine maintenance to remain effective.

Instanta CTS19F6 19 Litre Counter Top Water Boiler

£724.00(£868.80 inc VAT)

£724.00(£868.80 inc VAT)

The Instanta CTS19F6 is a counter top water boiler designed for commercial settings where a reliable, uninterrupted supply of hot water is needed throughout a full service period. It connects directly to a mains water supply and fills automatically, removing the need for manual refilling during service. Integrated point-of-use filtration is built in, which protects water taste, reduces scale accumulation, and removes the need for a separate inline filter unit.

In practice, this kind of unit earns its place in cafés, workplace restaurants, hotel serveries, and similar operations where hot beverage demand is steady rather than extreme. The capacity is sufficient to handle repeated rounds without the recovery pauses that can create pressure during a busy morning or lunchtime service. Electronic temperature control keeps the water at a consistent serving temperature across the day, so the first cup served and the last are drawn from water that is equally ready.

Day-to-day operational advantages include:

  • Integrated filtration protects water quality without additional inline equipment
  • Auto-fill operation keeps the boiler ready throughout service without manual intervention
  • Electronic temperature control maintains consistent water temperature across long service periods
  • Counter top footprint preserves floor space and keeps the unit accessible during service
  • Hardwired single-phase connection provides a stable, permanent supply suited to daily commercial use

Installation does require a hardwired single-phase electrical connection — a standard plug socket will not suffice, so electrical work should be planned and budgeted before the unit arrives. A mains cold water feed and an accessible stop valve are also needed at the installation point. It is worth checking that the counter surface can bear the weight of the unit when full before deciding on placement.

The CTS19F6 sits in a practical middle ground: more capable than a small top-up boiler, but appropriately sized for sites where a large floor-standing urn would be unnecessary. For operations with a high volume of covers in tight service windows, or where multiple service points need supplying simultaneously, a higher-capacity or higher-output model may be a better fit.

If you would like to talk through the unit's suitability for your service volume or installation setup, the team is happy to help before you place an order.